Studies show that, from an environmental point of view, improving insulation is preferable to replacing building services. However, they also show that a carefully selected heat pump (HP), combined with a mechanical ventilation system with heat recovery, can reduce the environmental impact of a new or renovated building. 

TOTEM (www.totem-building.be) can now be used to assess a building’s environmental impact, including that of its building services. Buildwise therefore assessed a well-insulated new building, in this case a 175.6 m² terraced house, under two scenarios. In the first scenario, featuring a gas boiler and a type C mechanical ventilation system without heat recovery, the impact of the materials used in the building services is 5% of the impact of the materials used in the building itself. In the second scenario, featuring an HP combined with a mechanical ventilation system with heat recovery, this figure rises to 17%. However, the total impact of the home fitted with an HP is lower, as the increased impact of the materials (from 5% to 17%) is offset by the reduced impact associated with energy consumption.

To maximise the benefits of reducing the impact of energy consumption, however, this increase in the impact of materials must be kept in check and, where possible, optimised. An HP alone accounts for 85% of the impact of materials used in building services, so it is crucial to choose one carefully. For units with the same performance, two criteria have a significant effect on environmental performance: the weight of the unit and the refrigerant used. 

A ‘lightweight’ unit requires fewer materials, so its manufacturing impact will be lower. In addition, since an HP will generally need to be replaced twice over a building’s service life, the resulting reduction in impact will be all the more significant.

The type of refrigerant used also has a major effect on environmental performance. If certain gases are released into the atmosphere following a leak during the use or end-of-life phases, the impact on climate change can be considerable. Note that, for now, the TOTEM tool does not account for leaks during the end-of-life phase of the installation. The CO2 equivalent of R134a refrigerant, for example, is around 475 times higher than that of propane. Regulations are currently being drawn up to ban certain types of refrigerant. The impact of harmful gases can also be reduced by choosing an installation that uses a limited quantity of gas or by minimising leaks.

To reduce the environmental impact of an uninsulated building, should you prioritise replacing the building services or installing insulation? TOTEM can now help users assess the options.

Let us apply two renovation scenarios to our example: replacing the building services rather than installing insulation (scenario 3), and carrying out a full renovation of the building (scenario 4).

Scenario 3 involves installing an HP and a mechanical ventilation system with heat recovery. The environmental impact associated with energy consumption is indeed greater than if the building were insulated, but lower than if the original gas boiler and mechanical ventilation system were retained in an uninsulated building. However, the building services need to be oversized to meet the higher energy demand compared with similar systems installed in an identical but insulated building. In addition, installing an HP requires modifications to the existing system. In particular, the low-temperature operating regime specific to HPs requires larger radiator surfaces to meet heating needs. This directly increases the environmental impact of the building services.

Scenario 4 involves insulating the external walls, as well as installing an HP and a mechanical ventilation system with heat recovery. Although its impact associated with materials is greater than that of scenario 3, its total environmental impact is lower. Insulation is therefore the preferred strategy for reducing a building’s environmental impact. 

This text is a shortened version of Buildwise article 2023/04.06, available at www.buildwise.be.

Étienne Douguet, researcher at Buildwise’s ‘Environmental Performance’ laboratory, and Lisa Wastiels, head of the laboratory

Question about this story? Ask your question

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeAlternative heating and cooling
  • SubjectNews
Share this article

Follow Installation & Construction

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.