A family of three all-inclusive ventilation units

Ventilair Group is launching a new family of all-inclusive ventilation units for balanced ventilation with heat recovery (System D), in three airflow capacities. The Vent-Axia Econiq is available in 300, 450 and 600 m3/h versions. These units come fully equipped to regulate indoor climate, with two integrated CO2 sensors, room sensors, controls and a free mobile app.
The three nominal airflow capacities available are 300, 450 and 600 m3/h. “The ideal operating points are at 150 Pa, but the unit has some headroom,” explains Steven Braekeveldt, Product and Marketing Manager at Ventilair Group. “All three units can actually operate with an external duct resistance of more than 200 Pa. This means the airflow at the valves is always achieved.”
“The units are optimised for EPB, but the most important thing is the energy efficiency of the unit as a whole,” continues Steven Braekeveldt. “We achieve an efficiency of 85% at nominal airflow rates, in line with EPB requirements. The unit has a constant volume and a 100% bypass. In addition, the motors consume less and are quiet thanks to the low internal resistance.”

All-inclusive
Extensions are available on the market for many ventilation units. The Vent-Axia Econiq units are different. “With other units, you always start with a stripped-down model and add features later,” explains Steven Braekeveldt. “But with the Vent-Axia Econiq units, everything is integrated: Bluetooth, Wi-Fi, radio frequency, an app, CO2 sensors, 0-10V inputs and Modbus.” Everything is included as standard. “This makes things easier not only for installers and logistics, but also for users.”
“The unit measures CO2, humidity and temperature, giving users an overview of indoor air quality through colour-coded diagrams in the app.” As well as the mobile app, the unit also has a screen that can be used to control it. “Users can always see what is happening, and installers can use it to check everything. Installers also have an installation assistant and a checklist to verify that the installation is compliant.”

Integrated CO2 sensor
The Vent-Axia Econiq units are equipped with two integrated CO2 sensors. “That’s unique,” says Steven Braekeveldt. “Installers don’t have to do anything. They buy a unit with an integrated CO2 sensor and immediately benefit from a reduction in the EPB score. When CO2 readings are poor, the system ventilates more than when they are good. This also saves energy. The sensors are always positioned on both sides, so the unit is also fully reversible digitally.

Easy configuration
Ventilair Group’s new family of ventilation units is easy to install, first and foremost because it has a practical design. “There are top and side connections. The units can be installed in a compact arrangement and close to the ceiling. And, of course, they are digitally reversible.”
Configuring the units is also straightforward. “The back office can prepare a configuration file in CSV format. It is then sent to the person commissioning the system, who can load the configuration onto the unit from their phone,” explains Steven Braekeveldt. “We can also copy functions from one unit to another. This can be very useful in an apartment building, for example.” Finally, Ventilair Group also offers RS485 mode, which allows the module to be controlled via the building management system.
“This unit is part of our complete solution,” concludes Steven Braekeveldt. “Last year, we also launched Uniflexplus+ 69, a low-pressure duct system, a Uniflexplus+ valve and a new range of insulated ducts … We offer installers a turnkey solution.”