Sanitary installations

Stop bacteria! How can you mitigate the risk safely?

Texte & photos Delabie

Le SPORTING 2 SECURITHERM intègre un mitigeur thermostatique dans la tête. Cette conception unique permet d’alimenter directement la douche à la température du réseau.
Le SPORTING 2 SECURITHERM intègre un mitigeur thermostatique dans la tête. Cette conception unique permet d’alimenter directement la douche à la température du réseau.

In healthcare facilities and public buildings alike, preventing bacterial growth in domestic water systems is a constant challenge. Infections caused by poor management of water system hygiene can be potentially serious. Mixing water as close as possible to the outlet is an effective way to tackle the problem. DELABIE solutions are designed with this in mind, helping to protect users’ health.

Over time, a natural film forms on the inside of pipes: biofilm. Bacteria in the water attach themselves to this layer, which provides favourable conditions for growth (moisture, temperature, nutrients, etc.). If left unchecked, bacterial growth in water systems can become a problem.

Among the bacteria naturally present, Legionella and Pseudomonas aeruginosa can cause serious healthcare-associated infections. They can be fatal for people with weakened immune systems.

The H9768BEL thermostatic shower mixer is designed to contain a very small volume of water and also features anti-scald protection.

In biofilm, Legionella grows at water temperatures between 25°C and 45°C. Outside this range, it remains dormant or is destroyed. Legionella infection occurs when users breathe in tiny water droplets containing the bacteria, sprayed into the air from outlets.

By contrast, Pseudomonas aeruginosa grows at water temperatures between 4°C and 42°C, with an optimum range of 30°C to 37°C. It needs air and water to proliferate, so it is mainly found in taps, flexible hoses and the first metre of pipework. Infection occurs through direct contact, via a wound or mucous membrane.

An effective technical solution to bacteria: mix water as close as possible to the outlet

Two measures are needed to prevent bacterial growth: minimise the volume of water stagnating in plumbing systems and ensure that hot water is above 55°C throughout the system.

When a branch pipe is connected to the hot water return loop, the water in the pipework leading to the sanitary fittings is only flushed when they are used. If they are not used regularly, the water stagnates and cools to a temperature that favours bacterial growth. All facilities subject to periods of low occupancy are affected, including hospitals, schools and tourist accommodation outside the season. This is why regulations for public buildings prohibit more than 3 litres of mixed water between the hot water loop and the outlet.

In biofilm, Legionella grows at water temperatures between 25°C and 45°C.

Mixing water as close as possible to the outlet brings the hot water loop close to the sanitary fittings. This ensures that water circulates at a high temperature, preventing microorganism growth. Once established in pipework, bacterial colonies are difficult to remove, so preventing them at the design stage is a winning strategy.

Regular flushing at the taps is also essential to renew the water and maintain high standards of hygiene throughout the system. All DELABIE electronic solutions provide automatic periodic flushing 24 hours after the last use, so there is no risk of it being forgotten.

PREMIX COMPACT can supply 2 to 10 water outlets. It provides stable temperature control and effective safety shut-off, even at low flow rates (5 l/min).

A closer look at some practical solutions 

For example, DELABIE’s SPORTING 2 SECURITHERM automatic shower column mixes water at the outlet, protecting users from scalding, and automatically carries out antibacterial flushing cycles. Mains- or battery-powered, it features an electronic control and a thermostatic mixer in the shower head. This system prevents mixed water from stagnating between the hot water loop and the outlet. The SPORTING design also ensures that no water is left unrenewed inside the panel.

Another example is DELABIE’s PREMIX mixers, installed as close as possible to the outlets, which reduce the temperature of the domestic hot water delivered by the taps. They therefore offer two key benefits: preventing bacterial growth in the system by allowing very hot water (> 55°C) to circulate, and protecting users from scalding. The PREMIX range also makes it easy to carry out thermal disinfection, providing periodic additional cleaning of water systems and outlets.    

A business enquiry for Delabie? Get in touch

Companies in this story

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeBetter domestic water management
  • SubjectSanitary installations
  • CompanyDelabie
Share this article

Advertisement

Follow Installation & Construction

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.