The impact of two-zone ventilation control
Texte Wouter Polspoel | Photos Ventiline

Ventilation is mandatory in every newly built home or home undergoing an energy renovation. A system with integrated two-zone control can deliver optimum efficiency. But what exactly is two-zone control? Ventiline, which offers such systems in its extensive range of high-quality ventilation systems, answers the question in this article. The ventilation specialist also highlights the practical benefits of a two-zone system.
A ventilation system with integrated two-zone control uses sensors to monitor indoor air quality by measuring CO2 levels and adjusting ventilation as needed. That last point, “as needed”, is important when it comes to system efficiency. A ventilation system with two-zone control divides the home into a day zone and a night zone: the area where occupants spend their time during the day and the area they use at night. It controls these two zones using separate valves.
For example, if everyone is in the living room and the ventilation system with integrated two-zone control detects CO2, which people exhale, only that space will be ventilated. At night, when everyone is in the bedrooms or night zone, the opposite happens. This can deliver energy savings of up to 40%, both thermal and electrical, compared with a ventilation system without two-zone control. The latter supplies fresh air to every room in the home, even where it is temporarily not needed.

Acoustic comfort
A ventilation system with two-zone control also benefits not only energy consumption but acoustic comfort, which is important in well-insulated new homes, where any noise in the house can be perceived as disturbing. Since such a system only needs to ventilate part of the home, rather than the entire house, the airflow rate is lower. The motors therefore do not need to run as fast, which has a positive impact on the noise level of the ventilation system. A reduction of up to 5 dB is realistic. Noise from the motor of a ventilation system is traditionally the main source of complaints.
Of course, correct system sizing is also important for good acoustics. A unit that has to run at full power all the time to maintain air quality will be noisier than one operating at 70% of its capacity, just as driving at 70 km/h in second gear is noisier than driving at 70 km/h in third gear. The same applies to duct calculations: an adequate diameter reduces turbulence noise, and enough attenuators must be installed. However, these are considerations that also apply to a ventilation system without two-zone control.

Positive impact on the E-level
A third major advantage of a ventilation system with two-zone control is that it provides a very attractive reduction factor (0.53) for the home’s final E-level. For a (partial) reconstruction project following demolition, the owner can benefit from a five-year reduction in property tax if they achieve a sufficiently low E-level. Two-zone control can make the difference between qualifying for the grant or not, without the need for any additional technology, apart from valves on the ventilation unit’s supply ducts. Valves have to be installed in any case.
Investing in a ventilation system with two-zone control therefore pays off straight away. The owner benefits from a reduction in property tax which generally exceeds the additional cost of the two-zone control in just one year. The investment therefore pays for itself after only one year, and the reduction applies for five years! What is more, the ventilation unit will also use less electricity, while air quality remains monitored at 100%. Investing in a ventilation system with two-zone control therefore benefits both the user’s finances and their health.
Een zakelijke vraag aan Orcon – Ventiline? Get in touch
Companies in this story
Keep following this
Get an email when a new story is published. No account needed.
- ThemeHealthy indoor air
- SubjectAir treatment
- CompanyOrcon – Ventiline